<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Iranian Journal of Health Insurance</title>
<title_fa>بیمه سلامت ایران</title_fa>
<short_title>Iran J Health Insur</short_title>
<subject>Medical Sciences</subject>
<web_url>http://journal.ihio.gov.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2645-8225</journal_id_issn>
<journal_id_issn_online>2645-4297</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1403</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2025</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>7</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مدیریت ثبت تعبیه و خروج دبل‌جی در اتاق عمل جهت جلوگیری از بروز دبل‌جی فراموش شده</title_fa>
	<title>Managing the Registration of Insertion and Removal of Double-J Catheters in the Operating Room to Prevent the Occurrence of Forgotten Double-J Catheters</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>گزارش کوتاه</content_type_fa>
	<content_type>Brief Report</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;color:#000000;&quot;&gt;&lt;span style=&quot;font-size:16px;&quot;&gt;&lt;span style=&quot;font-family:yekanYW;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;مقدمه: &lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt;خارج نشدن استنت دبل جی در موعد مقرر و باقی ماندن آن، عوارض زیادی برای بیمار به دنبال خواهد داشت.&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;در این مطالعه قصد داریم با توجه به اهمیت پیگیری و خارج سازی به موقع استنت&#8204;های دبل جی و اهمیت پیگیری بیماران، به بررسی دو رویکرد پیگیری و فالوآپ بیماران پس از اعمال جراحی اورولوژیک بپردازیم.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;روش بررسی: &lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt;این مطالعه از نوع گذشته نگر و در بیمارستان ضیائیان انجام شده است. تعداد ۵۷۳ بیمار طی مدت ۱۰ سال و در دوبازه زمانی ۵ ساله تحت تعبیه استنت دبل جی قرار گرفتند که از این میان تعداد ۸ بیمار واجد شرایط عنوان استنت دبل جی فراموش شده&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;بوده اند.&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot;&gt;&lt;span style=&quot;color:black&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;یافته&#8204;ها: &lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt;در&lt;/span&gt; &lt;span lang=&quot;FA&quot;&gt;&amp;nbsp;بازه زمانی ۵ ساله تعداد موارد تعبیه استنت دبل جی در بیمارستان ضیائیان ۲۲۴ مورد بوده است که تعداد ۷ مورد به علت عدم ادامه درمان پیگیری و در نتیجه عدم خروج استنت بستری شدند. در فاصله سال&#8204;های ۱۳۹۸ تا ۱۴۰۲ تعداد موارد تعبیه دبل جی، ۳۴۹ مورد بوده است که تعداد ۳ بیمار جهت پیگیری درمانی و خارج&#8204;سازی استنت دبل جی با سیستم پیگیری تلفنی فراخوانی شدند.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&lt;span style=&quot;direction:rtl&quot;&gt;&lt;span style=&quot;unicode-bidi:embed&quot;&gt;&lt;b&gt;&lt;span lang=&quot;AR-SA&quot;&gt;نتیجه&#8204;گیری: &lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;FA&quot;&gt;در این مطالعه تلاش شده است که نقش طراحی سیستم&#8204;های کم هزینه پیگیری جهت ادامه درمان بررسی&#8204;های پساجراحی، به&#8204;صورت شفاف ارائه شود تا پزشکان و سایر کادر درمان به اهمیت ارائه و طراحی یک نظام هماهنگ، ساده&#8204;سازی شده، عملیاتی و ارزان قیمت در پیگیری منسجم بیماران پی ببرند.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;span style=&quot;color:#000000;&quot;&gt;&lt;span style=&quot;font-size:14px;&quot;&gt;&lt;span style=&quot;font-family:Times New Roman;&quot;&gt;&lt;span style=&quot;line-height:2;&quot;&gt;&lt;b&gt;&lt;span lang=&quot;EN&quot;&gt;Introduction:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;EN&quot;&gt; Failure to remove a Double-J stent on time and its retention will result in many complications for the patient.&lt;/span&gt; &lt;span lang=&quot;EN&quot;&gt;In this study, we intend to examine two approaches to follow-up and follow-up of patients after urological surgeries, considering the importance of timely follow-up and removal of Double-J stents and the importance of patient follow-up.&lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; dir=&quot;RTL&quot; style=&quot;font-family:&quot;Times New Roman&quot;,serif&quot;&gt;&lt;/span&gt;&lt;br&gt;
&lt;b&gt;&lt;span lang=&quot;EN&quot;&gt;Methods:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;EN&quot;&gt; This retrospective study was conducted at Ziaeian hospital.&lt;/span&gt; &lt;span lang=&quot;EN&quot;&gt;A total of 573 patients underwent Double-J stent implantation over a period of 10 years and in two 5-year periods, of which 8 patients were eligible for the title of forgotten Double-J stent. &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; dir=&quot;RTL&quot; style=&quot;font-family:&quot;Times New Roman&quot;,serif&quot;&gt;&lt;/span&gt;&lt;br&gt;
&lt;b&gt;&lt;span lang=&quot;EN&quot;&gt;Results:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;EN&quot;&gt; During the 5-year period, the number of Double-J stent implantation cases at Ziaeian hospital was 224, of which 7 cases were hospitalized due to failure to continue follow-up treatment and as a result, failure to remove the stent. Between 2019 and 2023, the number of Double-J stent implantations was 349, of which 3 patients were called for follow-up treatment and removal of the Double-J stent using a telephone follow-up system. &lt;/span&gt;&lt;span lang=&quot;AR-SA&quot; dir=&quot;RTL&quot; style=&quot;font-family:&quot;Times New Roman&quot;,serif&quot;&gt;&lt;/span&gt;&lt;br&gt;
&lt;b&gt;&lt;span lang=&quot;EN&quot;&gt;Conclusion:&lt;/span&gt;&lt;/b&gt;&lt;span lang=&quot;EN&quot;&gt; This study attempts to present the role of designing low-cost follow-up systems for continuing treatment and postoperative examinations in a transparent manner so that physicians and other medical staff realize the importance of providing and designing a coordinated, simplified, operational, and inexpensive system for coherent patient follow-up.&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-size:12pt&quot;&gt;&lt;span style=&quot;line-height:200%&quot;&gt;&lt;span rockwell=&quot;&quot; style=&quot;font-family:&quot;&gt;&lt;span lang=&quot;AR-SA&quot; dir=&quot;RTL&quot; style=&quot;font-family:&quot;Times New Roman&quot;,serif&quot;&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/span&gt;&lt;/div&gt;</abstract>
	<keyword_fa>تعبیه, دبل جی, بروز مجدد دبل جی</keyword_fa>
	<keyword>Embedding, Double-J, Re-emergence of Double-J</keyword>
	<start_page>277</start_page>
	<end_page>282</end_page>
	<web_url>http://journal.ihio.gov.ir/browse.php?a_code=A-10-671-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Ali</first_name>
	<middle_name></middle_name>
	<last_name>Tavoosian</last_name>
	<suffix></suffix>
	<first_name_fa>علی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>طاوسیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>alitavoosian@gmail.com</email>
	<code>10031947532846006036</code>
	<orcid>10031947532846006036</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Urology, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه ارولوژی، دانشکده پزشکی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Sana</first_name>
	<middle_name></middle_name>
	<last_name>Ahmadi</last_name>
	<suffix></suffix>
	<first_name_fa>ثنا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>احمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>SANAAHMADI750525@GMAIL.COM</email>
	<code>10031947532846006037</code>
	<orcid>10031947532846006037</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>School of Medicine, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>دانشکده پزشکی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mehdi</first_name>
	<middle_name></middle_name>
	<last_name>Rezaee</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رضایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>MEHDI96@GMAIL.COM</email>
	<code>10031947532846006038</code>
	<orcid>10031947532846006038</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Orthopedics, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه ارتوپدی، دانشکده پزشکی، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
